Circulation Arteries
I am showing 2 distinct circulation paths (interior/exterior) the interior circulation will go completely around the track area. and it will go behind the main seating areas to not obstruct the view of the track then on the 2 ends it will go between the track and commercial/retail areas so that the commercial/retail areas can have direct access to the exterior of the building for their main entrances. This allows people from these areas to view the track from their space without giving direct access to the track area seating. This also allows these areas (commercial/retail) to be open when the track is not. Also on this plan I am showing exterior bike storage across from the exterior glass wall allowing people to store their road, mountain and/or cross bikes outside the facility so they can keep them on site and not have to transport them to and from home. This allows someone who works in downtown OKC the convenience to use the facility without having to take their bike with them to work and have to load/unload it and take it into their office building with them and keep track of it all day.
LEED Goals
Code Analysis
1005.1 Egress:
0.2in/occupant Stairs, 0.15in/occupant Other- Sprinkled
1024 Assembly
1024.6.1-2 At least0.005in of additional stair width for each occupant shall be provided for each 0.10in of riser above 7in
1024.7 Travel Distances- Exits and Aisles shall be so located that the travel distance to an exit door shall not be greater than 250ft in sprinkled buildings.
1024.9.1 Minimum aisle width-
1. Forty-eight inches for aisle stairs having seating on each side
2. Thirty-six inches for aisle stairs having seating only one side
4. forty-two inches for level or ramped aisles having seating both sides
5. thirty-six inches for level or ramp aisles having seating only one side
1108.2.2.1 Accessible Wheel Chair spaces (seating)- (6+4)= 10 total
Below is my FULL Code Analysis for my building.
0.2in/occupant Stairs, 0.15in/occupant Other- Sprinkled
1024 Assembly
1024.6.1-2 At least0.005in of additional stair width for each occupant shall be provided for each 0.10in of riser above 7in
1024.7 Travel Distances- Exits and Aisles shall be so located that the travel distance to an exit door shall not be greater than 250ft in sprinkled buildings.
1024.9.1 Minimum aisle width-
1. Forty-eight inches for aisle stairs having seating on each side
2. Thirty-six inches for aisle stairs having seating only one side
4. forty-two inches for level or ramped aisles having seating both sides
5. thirty-six inches for level or ramp aisles having seating only one side
1108.2.2.1 Accessible Wheel Chair spaces (seating)- (6+4)= 10 total
Below is my FULL Code Analysis for my building.
okc_velodrome_code_analysis.docx |
Occupancy Type & Plumbing Calculations: These are really rough plumbing calc numbers. Obviously the sq ft of the seating area is to large since I am only looking at holding 1,000 seats. Items and numbers will be updated as I design the facility and have better sq ft numbers.
Parking Requirements:
Theaters- 1 space per 4 seats (380)
Retail- 1 per 200 sq ft up to 12,000 sq ft (60) 65,514 total sq ft
1 per 225 sq ft 12,001 to 48,000 (143)
1 per 250 sq ft over 48,001 sq ft (70)
Total Spaces: 653
Handicap: 13
Regular: 640
Theaters- 1 space per 4 seats (380)
Retail- 1 per 200 sq ft up to 12,000 sq ft (60) 65,514 total sq ft
1 per 225 sq ft 12,001 to 48,000 (143)
1 per 250 sq ft over 48,001 sq ft (70)
Total Spaces: 653
Handicap: 13
Regular: 640